Indirect Heating
Cabinet heaters
- Catalytic Cabinet Heater No carbon monoxide produced
- 3 Heat Settings up to 3.0 KW
- Oxygen depletion and flame failure safety system
- Child safe with lower touch temperatures
- Additional child guard available
- Butane fired using 15Kg Cylinder
PATIO HEATERS
- 5m diameter Warming Area
- 40,000 BTU of Heating
- Propane Fired using 13 or 15Kg Cylinders
- Available in stainless steel, black or green
- Robust design free standing unit
- Maximum Running Time 37 hrs (13Kg)
- Ideal for heating outdoor hospitality and patio areas.
All of our products carry 12 month warranties ensuring total satisfaction for all our customers.
All our products are supported by years of experience in both manufacture and development.
They are built using the most up to date technology.
Professional site heaters
- Radiant heating
- Instant heat
- No oxygen consumption
- No air flow, no dust
- No fumes, no odours, no humidiity
- Low noise
- 100% Efficiency
- Variable heat settings
- Strong and long lasting construction
Close environments.
Agriculture, Construction, Garages, Shops, Houses, Offices, Cellars, Warehouses.
Recommended for painters, plasterers, tile setters, plumbers, etc.
| Features | TS 3A | HALL 1500 | HALL 3000 | HALL 3000 C | |
| Capacity: | kW | 0.8- 1.6- 2.4 | 1.5 | 1.5-3 | 1.5-3 |
| Btu/h | 2,700- 8,200 | 5,100 | 5,100 - 10,200 | 5,100 - 10,200 | |
| Kcal/h | 690- 2,070 | 1,290 | 1,290 - 2,580 | 1,290 - 2,580 | |
| Energy consumption: | Amp. | 10.5 | 6.5 | 13 | 13 |
| Voltage: | V/Hz | 230 - 240/50 | 230 - 240/50 | 230 - 240/50 | 230 - 240/50 |
| Packaging LxWxHt: | cm | 38 x 24 x 46 | 54 x 25 x 32 | 55 x 34 x 64 | 80 x 28 x 53 |
| Net weight: | kg | 7.4 | 4.8 | 12 | 14 |
| Gross weight: | kg | 8 | 5.7 | 13 | 15 |
| Pallet: | pcs | 36 | 36 | 12 | 16 |
COMMERCIAL / DOMESTIC ELECTRICAL HEATERS
HN20/2 2kw Convector Heater
- Modern Styling.
- Thermostat to control temperature.
- Wall mount brackets included.
- All models 42cmH x 61cmW x 17cmD
Infra Red Heaters
Infra 3s
- Head output - 10200BTU (3kw)
- Approx heated area - 2582ft3 (73m3)
- Voltage - 230v or 110v

Infra 3c
- Head output - 10200BTU (3kw)
- Approx heated area - 2582ft3 (73m3)
- Voltage - 230v or 110v
ELECTRIC FAN HEATERS


- No oxygen consumption
- No fumes, no odours, no humidiity
- Low noise
- 100% Efficiency
- Motor with thermal protection
- Stainless steel heating elements
- Overheat thermostat
- Built-in room thermostat
- Variable heat, 4 position switch
- Strong and long lasting construction
Close environments.
Agriculture, Construction, Garages, Shops, Houses, Offices, Cellars, Warehouses.
Recommended for painters, plasterers, tile setters, plumbers, etc.
For maximum drying efficiency use with a MASTER dehumidifier.
| Features |
B 2 | B 3 |
B 5 | B 9 |
B 15 | B 22 | |
| Capacity: | kW | 1-2 | 1.5-3 | 2.5-5 | 4.5-9 | 7.5-15 | 11-22 |
Btu/h | 3,440
- | 5,160 - | 5,600
- | 15,480 - | 25,800
- | 37,840 - | |
- 6,800 | -
10,320 | - 17,200 | -
30,960 | - 51,600 | -
75,680 | ||
Kcal/h | 860
- | 1,290 - | 2,150
- | 3,870 - | 6,450
- | 9,460 - | |
- 1,720 | -
2,580 | - 4,300 | -
7,740 | - 12,900 | -
18,920 | ||
| Current consumption max: | Amp. | 8.6 | 13 | 7.2 | 13 | 21.7 | 32 |
| Voltage: | V/Hz | 230
/ 50 | 230 / 50 | 400
/ 3-50 | 400 / 3-50 | 400
/ 3-50 | 400 / 3-50 |
| Air displacement: | m³/h | 350 | 400 | 450 | 780 | 990 | 2,200 |
| Thermostat control: | standard | standard | standard | standard | standard | standard | |
| Packaging LxWxHt: | cm | 22
x 24 x 43 | 29 x 28 x 43 | 29
x 36 x 41 | 34 x 44 x 54 | 38
x 48 x 53 | 52 x 58 x 64 |
| Net weight: | kg | 4 | 6 | 7 | 11 | 16 | 23 |
| Gross weight: | kg | 5 | 7 | 9 | 13 | 19 | 26 |
| Pallet: | pcs | 75 | 48 | 40 | 20 | 15 | 12 |

DE95
- Head output - 68000BTU (20kw)
- Approx heated area - 17211ft3 (487m3)
- Voltage - 415v
INDIRECT FIRED MOBILE HEATING
- Standard photocell cut off
- Electronic flame control
- Overheat and post-ventilation thermostats
- Possible connection to an optional room thermostat
- Stainless steel combustion chamber
- Heat exchanger
- Durable external painted finish
- Strong and long lasting construction
- Housing remains cool to the touch
- Easy maintenance with external pump
- High air flow
fields of application
Warehouses, workshops, building applications, greenhouses and animal housing.
| Features | BV 170 E | BV 290 E | BS 170E | BS 290 E | |
| Capacity: | kW | 47 | 81 | 65 | 105 |
| Btu/h | 160.000 | 280.000 | 224.000 | 360.000 | |
| Kcal/h | 40.000 | 70.000 | 56.000 | 90.300 | |
| Air displacement: | m³/h | 1.800 | 3.300 | 1.800 | 3.300 |
| Fuel: | kerosene / diesel oil | ||||
| Oil consumption: | kg/h | 3,8 | 6,8 | 3,9 | 5,1 |
| Tank capacity: | lt | 65 | 105 | ||
| Electrical power: | kW | 0,5 | 1,06 | 0,5 | 1,06 |
| Energy consumption: | Amp. | 2,3 | 4,6 | 2,3 | 4,6 |
| Flue tube: | mm | 150 | 150 | - | - |
| Blast opening Ø: | mm | 350 | 400 | - | - |
| Thermostat control: | possible | possible | possible | possible | |
| Net weight: | kg | 72 | 123 | 58 | 87 |
| Gross weight: | kg | 85 | 144 | 78 | 107 |
We can supply flue systems with all indirect heaters
High Output Indirect heaters
- Separate oil burner
- Standard photocell cut off
- Electronic flame control
- Fan-limit thermostat with automatic reset
- Limit thermostat with manual reset
- Possible connection to an optional room thermostat
- Summer-Winter switch for ventilation only
- Standard Fuel pre-heating
- Four way air-outlet panel
- Possibility of canalization
- Standard trolley
- Stainless steel combustion chamber
- Heat exchanger with high efficiency
- Aluminium structural frame
- External Painted Steel Double Plate
| Features | BV 300 E | BV 360 E | BV 460 E | BV 680 E | |
| Capacity: | kW | 81 | 105 | 134 | 220 |
| Btu/h | 280.000 | 360.000 | 460.000 | 760.000 | |
| Kcal/h | 70.000 | 90.000 | 115.000 | 190.000 | |
| Air displacement: | m³/h | 5.000 | 6.000 | 8.000 | 12.500 |
| Fuel*: | diesel oil | diesel oil | diesel oil | diesel oil | |
| Oil consumption: | kg/h | 6,9 | 8,8 | 11,3 | 18,6 |
| Tank capacity: | lt | - | - | - | - |
| Electrical power: | kW | 0,55 | 0,75 | 1,1 | 2,2 |
| Energy consumption: | Amp. | 4,8 | 6,2 | 7,3 | 12,4 |
| Flue tube: | mm | 150 | 150 | 200 | 200 |
| Blast opening Ø: | mm | 1x450 | 1x500 | 4x300 | 4x300 |
| Thermostat control: | possible | possible | possible | possible | |
| Net weight: | kg | 154 | 160 | 195 | 360 |
| Gross weight: | kg | 168 | 178 | 215 | 385 |
INDIRECT FIRED HEATERS
BV
80 A BV 110E BV178 E BV 290E Specifications
- With heat exchanger and flue tube
- Clean heat and high efficiency
- Standard photocell cutoff
- Easy to service and maintain with standard replacement parts
- Housing remains cool to the touch
- Combustion system is adjustable for clean combustion
- Full automatic operation with room thermostat
- High air displacement
- Overheat switch protection
| BV 80 A | BV 100E | BV178 E | BV 290E | ||
| CAPACITY | kW Btu/h. | 23 80000 | 29 100000 | 47 160000 | 81 280000 |
| AIR DISPLACEMENT | m3/h | 1200 | 1500 | 1800 | 3300 |
| FUEL CONSUMPTION | Kg/h | 1.96 | 2.4 | 3.9 | 6.8 |
| FUEL | diesel oil | diesel oil | diesel oil | diesel oil | |
| TANK CAPACITY | It. | 41 | 65 | 65 | 105 |
| ELECTRICAL POWER | kW | 0.35 | 0.29 | 0.48 | 1.14 |
| CURRENT TYPE | AC | AC | AC | AC | |
| VOLTAGE | V/Hz | 230 / 50 or 110 / 50 | 230 / 50 or 110 / 50 | 230 / 50 or 110 / 50 | 230 / 50 or 110 / 50 |
| DIMENSIONS LxWxHT | cm | 118 x 51 x 92 | 122 x 51 x 102 | 136 x 51 x 102 | 165 x 72 x 106 |
| NET WEIGHT | kg | 53 | 66 | 72 | 123 |
| GROSS WEIGHT | kg | 61 | 79 | 85 | 144 |
| THERMOSTAT CONTROL | optional | optional | optional | optional | |
| FLUE TUBE Ø | mm | 150 | 150 | 150 | 150 |
| BLAST OPENING Ø | mm | 300 | 350 | 350 | 400 |
WASTE OIL FIRED MANUAL IGNITION ECONOMY HEATERS
![]() | Thermobile waste oil fired heaters can be operated using waste oil from diesel or petrol engines, gearboxes, transmissions, hydraulic systems, diesel oil or any combination of these. The following must not be used; solvents, thinners, petrochemical based oils, transformer oil or any oil above S.A.E. 90.Full combustion is achieved in a vaporising system and non burnable residue is retained in the burner pan. This system does not produce any unpleasant smell or smoke and the emissions from the flue stack are well below permitted contamination levels. |

- CLEAN, SOOT FREE COMBUSTION
- CAN BURN PURE WASTEOIL OR MIXED WITH DIESEL
- FAST RETURN ON INVESTMENT DUE TO FREE FUEL
- HIGH EFFICIENCY
- HEATER INCLUDES BUILT-IN-TANK, PUMB & CONTROLS
(1) Output depending on type of waste oil. (2) Depending on building insulation.
|
|
| INFORMATION RELATING TO FLUE PIPING The standard flue kit consists of: Models
AT306, AT307 & AT400 Model
AT500
Supports A Guy Wire fixing bracket is available to provide extra lateral support where the flue extends more than 1.5m above the last wall band, or for inter-connection with the roof flashing. | Roof
Penetrations Storm collars of aluminium are also available and should be fitted to the pipe immediately above the flashings. Terminations Rain caps are not permitted with waste oil fired heaters. The terminal pipe is designed to deflect rain water down the outer section. NB. All lengths and fittings are fabricated from 0.55mm Type 430 Stainless Steel. |
| Ray Lane Business Park, Kenlis Road, Barnacre, Preston, PR3 1GD. |
| TEL : 01995 601000 | FAX : 01995 600966 |