Heating
We are nominated
sole distributors for 4 leading manufacturers of space heaters,
including world famous Powrmatic heaters. Therefore, we are
able to supply a range of oil and gas fired portable and fixed
heaters suitable for all your business needs.
We can supply - OFFICES, WAREHOUSES,
FACTORIES, WORKSHOP,
SCHOOLS, etc
Our high quality
service provides all our customers with a first class repairs
and servicing department as well as a comprehensive range
of spares.
We
have many years experience of supplying instant heat for both
corporate and public events such as exhibitions, marquees
and temporary structures, concerts, sporting and leisure events,
television and film sets.
Typically
this has been supplied using indirect, oil fired heaters that
deliver large volumes of clean, dry, warm air without any
of the byproducts of combustion and negating the risk from
naked flames.
|
Page Contents
- Atmospheric Gas Fired and Oil
- Fired Ranges
- Radiant - Gas Fired Tube Heaters
- Rinnai - Hot Water Systems
- Gas Fired Door Curtain Heaters
- Powrmatic's Eurotrol 2
- Rinnai - Fanned Convection powered flue heaters
- OUH - Oil Unit Heaters
- Calecon - Thermal Economiser
- PGUH - Gas Unit Heater
- Powrtrol - Energy Saving Equipment
- PAG - Indirect Fired Warm Air Cabinet
Heater
- Cabinet - Indirect Fired Heaters
- DFU - Direct Fired Unit
- Waste Oil Fired Manual Ignition
Economy Heater
|
|
ATMOSPHERIC GAS FIRED AND OIL - FIRED RANGES
|
 |
The
extensive series of boilers consists of five ranges, available
in heat outputs from 19kW to 279kW, providing ideal solutions
for domestic, commercial and industrial applications.
This
value engineered series offers high efficiency, quiet and
clean operation, reliability, ease of installation and maintenance
, and perhaps more importantly, user friendliness.
|
|
RADIANT - GAS FIRED TUBE HEATERS
|
 |
The
new range of gas fired radiant tube heaters provide direct
heat and warmth in a multitude of industrial, commercial
and retail applications. The range is available in three
types comprising 'U' tubes, single linear and double linear
tube.
|
Dimensions and Specifications for Single Linear Tube Models
| MODEL |
PTS09
|
PTS12
|
PTS15
|
PTS25
|
PTS30
|
PTS35
|
PTS40
|
PTS45
|
| Input
Rating - kW |
9.00
|
11.40
|
15.00
|
23.00
|
29.20
|
34.50
|
42.20
|
47.00
|
| Lenght
(A) - mm |
5493mm
|
5493mm
|
5493mm
|
10065mm
|
9955mm
|
9955mm
|
13000mm
|
13000mm
|
| Width
(B) - mm |
340mm
|
340mm
|
340mm
|
340mm
|
340mm
|
340mm
|
340mm
|
340mm
|
| Height
(C) - mm |
180mm
|
180mm
|
180mm
|
180mm
|
180mm
|
180mm
|
180mm
|
180mm
|
| Heater
Weight - Kg |
33kg
|
33kg
|
33kg
|
46kg
|
62kg
|
62kg
|
79kg
|
79kg
|
| Gas
Connection |
R
- 1/2" BSP External
|
| Supply
Pressure |
Natural
Gas - Min 17, Max 25 Propane - Min 25, Max 45 Butane - Min
20, Max 35
|
| Electrical
Supply - mbar |
230v
50Hz 125w, Current rating 0.55A, Fuse externally 3A
|
| Flue
Connection Diameter - mm |
127mm
|
| Air
Inlet Diameter - mm |
101.6mm
|
top
|
RINNAI - INFINITY WATER HEATERS
|

|
Rinnai
continuous flow
hot water systems
only rinnai offers you the coomplete package
Our innovative heat exchanger design allows us to provide
you with the largest capacity flow rates, whilst ensuring
near mains pressure - you get all the hot water you
need, when you need it.
- Largest
capacities on the market
- Near
mains pressure flow
- Complete
with one digital controller, but capable of having
4 controllers
- CE
and WRAC approved
- Frost
protection on all units as standar
|
Dimensions
|
Model
|
Rinnai
Infinity 24e external
|
Rinnai
Infinity 26i internal
|
Rinnai
Infinity 32e external
|
|
Installation
|
External
Wall Mounted
|
Internal
Wall Mounted
|
External
Wall Mounted
|
| Height
(A) |
600mm |
600mm |
600mm |
| Width
(B) |
350mm |
350mm |
470mm |
| Depth
(C) |
170mm |
224mm |
220mm |
| Weight |
15kg |
22kg |
29kg |
| Exhaust
system |
Forced
Exhaust |
Direct
Vent Forced Flue |
Forced
Flue |
| Tempreature
Range |
37C
- 55C |
37C
- 55C |
37C
- 55C |
| Ignition
Method |
Direct
electronic ignition |
Direct
electronic ignition |
Direct
electronic ignition |
| Gas
Consumption (natural) |
5.8KWh
low - 52 KWh max |
4.3KWh
low - 54 KWh max |
5.5KWh
low - 69 KWh max |
| Gas
Consumption (Propane) |
5.8KWh
low - 52 KWh max |
4.3KWh
low - 54 KWh max |
5.5KWh
low - 69 KWh max |
| Hot
Water Delivery Capacity |
18L
/ min raised 33C |
19.6L
/ min raised 33C |
24L
/ min raised 33C |
| Min
operating pressure |
2.7L/min |
2.7L/min |
2.7L/min |
| Nominal
operating pressure |
1.4-8.3
bar |
1.4-8.3
bar |
1.4-8.3
bar |
| Power
Supply |
AC
230 V (50Hz) |
AC
230 V (50Hz) |
AC
230 V (50Hz) |
| Electrical
consumption |
55W |
80W |
83W |
|
ULTRADOR - GAS FIRED DOOR CURTAIN HEATERS
|

|
Ultrador
is a high efficient gas-fired heater designed primarliy
to provide a warm air curtain across frequently opened
doors to prevent cold draughts and heat loss.
- energy
efficient (92.5% combustion efficiency)
- Enhanced
capital allowance (ECA) approved
- Clean
and quiet operation
- Simple
to install
- Ideal
replacement for inefficient electric or lphw units
- Comoplete
wit 50mm flexible flue pack
- Simple
to maintain
- Two
years parts and labour guarantee
- High
specification control and mounting bracket options
|
Dimensions
|
Model
|
A
|
B
|
C
|
D
|
E
|
F
|
G
|
H
|
I
|
J |
K |
| |
mm
|
mm
|
mm
|
mm
|
mm
|
mm
|
mm
|
mm
|
mm
|
mm |
mm |
|
UD
10
|
1600
|
582
|
300
|
282
|
1264
|
386
|
193
|
80
|
241
|
65 |
54 |
Technical Specifications
| MODEL |
Heat
Input
Kw
|
Heat
Output
Kw
|
Gas
Rate
M3/h
|
Air
Velocity
m/s
|
Air
Volume m3/s
|
Noise
Level
dB (a)
|
Weight
Kg
|
| UD
10 |
10.81
|
10.00
|
1.14
|
5.1
|
0.26
|
53
|
83
|
Electrical data
| MODEL |
Electrical
Supply
volts
|
Motor
Size
Kw
|
Start
Current
Amps
|
Run
Current
amps
|
| UD
10 |
240-1ph
|
0.184
|
3.01
|
1.24
|
top
 |
For
Enhanced Capital Allowance (ECA) eligibility Ultrador
must be controlled by Powrmatic's latest high specification
heating controller, the Eurotrol 2. Although sophisticated,
it is very simple to operate and provides, as standard,
ideal features for energy efficient door curtain control.
- Optimum
on/off
- simple
to program and opetate
- digitatal
time clock with three time and tempreture periods
per day
- Maitains
deign tempreture to +/- 0.5C
- Constant
run fan
- fan
only option
- Remote
reset for burner lock out
- Frost
protection
- Night
set back facility
- service
warning indicating contact name and telephone
- housrs
run and energy cost log
- Comprehensive
access and security features
|
|
RINNAI - FANNED CONVECTION POWERED WALL HEATERS
|
|
|
Rinnai
556T, 556FTR, & 1004T
Rinnai Fanned Convection powereed flue heaters were
introduced into the UK in 1979 and have earned a well
deserved reputaion for providing safe in 1979 and have
earned a well deserved reputation for providing safe
controllable heat with maximum effiency in the use of
gas, combined with flexibility of location.
The Rinnai heaters are manufactured in japan and , as
you would expect, have a modern apperance and advanced
technology, together with high efficiency and reliability.
- Flame
failure protection
- automatic
ignition
- Central
or integral time clocks**
- Remote
control**
- Floor
standing
- Warm
air at floor level
- Integral
Air Filters
- Fully
modulating fans and burners
- Flexible
flue extension system
- Fan
assisted flue
- Low
noise levels
- Stainless
steel heat exchanger
**(556
FTR only)
|
Dimensions
& Specifications
|
Model
|
Rinnai
Infinity 5565T, 556FTR
|
Rinnai
1004T
|
|
Input
|
6.4Kw/21837
Btu/h
|
11.6Kw/39780
Btu/h
|
| Output
|
5.2Kw/17742
Btu/h |
10.2Kw/34900
Btu/h |
| Height
(A) |
554mm |
670mm |
| Width
(B) |
250mm |
315mm |
| Depth
(C) |
750mm |
930mm |
| Standard
Flue |
240mm-400mm
|
240mm
- 400mm |
| Alternative
Flues to fit walls: |
75mm-1000mm |
75mm
- 1000mm |
| Flue
Hole Diameter |
80mm
|
80mm |
| Other
Notes |
5.8KWh |
4.3KWh
low |
FTR
model incorporates a 24 hour timer and remote control
OUH
20 Model
OUH 30 - 60 Models
|

OUH
units are indirect oil fired suspended air heaters with
stainless steel heat exchangers as standard and a downwards
firing pressure jet oil burner. The range has been designed
for use in factory or warehouse premises where oil firing
is a requirement and floor space is at a premium
|
|
Model
|
Model
|
A
|
B
|
C
|
D
|
E
|
F
|
G
|
H
|
K
|
L
|
| |
|
mm
|
mm
|
mm
|
mm
|
mm
|
mm
|
mm
|
mm
|
mm
|
mm
|
|
OUH
20
|
F
|
610
|
555
|
210
|
745
|
100
|
435
|
115
|
555
|
408
|
342
|
|
C
|
610
|
555
|
210
|
1085
|
100
|
435
|
115
|
555
|
408
|
342
|
|
OUH
30/45/60
|
F
|
847
|
780
|
255
|
1030
|
125
|
490
|
210
|
500
|
640
|
420
|
|
C
|
847
|
780
|
255
|
1468
|
125
|
490
|
210
|
500
|
640
|
420
|
|
CALECON
- THERMAL ECONOMISER
|

| Model |
A
|
B
|
| |
mm
|
mm
|
| CEC
1250 |
500
|
357
|
| CEC
2250 |
600
|
357
|
| CEC
3750 |
655
|
357
|
| CEC
6500 |
805
|
357
|
|

It
is a basic law of physics that hot air rises and in high
roofed buildings this will cause a temperature gradient
with hot air under the roof and cooler air at floor level.
Calecon thermal economiser units will automatically recirculate
high level hot air, reducing stratification and associated
heat losses.
|
 |
The
new range of gas unit heaters are designed to offer
warm air heating solutions to areas where floor space
is at a premium. The design concept was established
in conjunction with end users, installers and service
engineers ensuring a range that is pleasing to the eye,
energy efficient, easy to install and easy to maintain.
The range is available with a wide range of control
and modular duct components offering an ideal heating
package for most industrial and commercial premises. |
|
Model
|
A
|
B
|
C
|
D
|
E
|
F
|
G
|
H
|
J
|
K
|
L
|
M |
N |
O |
P |
Q |
|
NV
10F
|
590
|
750
|
700
|
109
|
120
|
250
|
181
|
296
|
135
|
455
|
120
|
80 |
116 |
189 |
83 |
510 |
|
NV
15F
|
590
|
1000
|
700
|
109
|
120
|
250
|
181
|
506
|
176
|
455
|
120
|
80 |
116 |
189 |
83 |
510 |
|
NV
20F
|
590
|
1000
|
700
|
109
|
120
|
250
|
181
|
506
|
176
|
455
|
120
|
80 |
116 |
189 |
83 |
510 |
|
NV
25F
|
590
|
1000
|
700
|
109
|
120
|
250
|
181
|
506
|
176
|
455
|
120
|
80 |
116 |
151 |
83 |
510 |
| NV
30F |
818
|
1000
|
700
|
124
|
142
|
235
|
173
|
506
|
176
|
455
|
120
|
100 |
116 |
227 |
83 |
738 |
| NV
40F |
818
|
1000
|
700
|
124
|
142
|
235
|
173
|
506
|
176
|
455
|
120
|
100 |
116 |
151 |
83 |
738 |
| NV
50F |
970
|
1000
|
700
|
124
|
142
|
235
|
173
|
506
|
176
|
455
|
120
|
100 |
116 |
151 |
83 |
890 |
| NV
60F |
818
|
1345
|
700
|
124
|
220
|
235
|
202
|
740
|
258
|
455
|
120
|
130 |
146 |
151 |
83 |
738 |
| NV
75F |
970
|
1345
|
700
|
124
|
220
|
235
|
202
|
740
|
258
|
455
|
120
|
130 |
146 |
151 |
83 |
890 |
| NV
90F |
705
|
2345
|
700
|
124
|
220
|
235
|
202
|
870
|
258
|
455
|
120
|
130 |
88 |
153 |
83 |
624 |
| NV
120F |
870
|
2345
|
700
|
124
|
220
|
235
|
202
|
870
|
258
|
455
|
120
|
130 |
88 |
153 |
83 |
789 |
| NV
140F |
1035
|
2345
|
700
|
124
|
220
|
235
|
202
|
870
|
258
|
455
|
120
|
130 |
88 |
401 |
83 |
954 |
|
Model
|
Input
Kw
|
Output
Kw
|
Gas
Rate m3/h
|
Air
Volume m3/h
|
Throw
m
|
Fan
Motor
Kw
|
Start
Current
A
|
Run
Current
A
|
Noise
Level
dB(A)@3
|
Weight
Kg
|
|
NV
10F
|
10.79
|
10.00
|
0.70
|
0.26
|
6
|
0.03
|
0.76
|
0.35
|
46
|
53
|
|
NV
15F
|
16.00
|
15.00
|
0.87
|
0.39
|
6
|
0.10
|
1.98
|
0.68
|
54
|
54
|
|
NV
20F
|
21.85
|
20.00
|
1.23
|
0.52
|
9
|
0.06
|
1.50
|
0.49
|
52
|
68
|
|
NV
25F
|
27.32
|
25.00
|
1.75
|
0.65
|
11
|
0.08
|
1.51
|
0.68
|
53
|
72
|
| NV
30F |
32.60
|
30.00
|
1.94
|
0.78
|
13
|
0.08
|
1.51
|
0.68
|
54
|
89
|
| NV
40F |
43.48
|
40.00
|
2.56
|
1.04
|
13
|
0.15
|
2.78
|
1.35
|
58
|
93
|
| NV
50F |
54.23
|
50.00
|
3.01
|
1.3
|
19
|
0.20
|
3.16
|
1.62
|
61
|
114
|
| NV
60F |
65.22
|
60.00
|
3.77
|
1.56
|
22
|
0.25
|
3.03
|
1.01
|
62
|
130
|
| NV
75F |
81.25
|
75.00
|
4.51
|
1.95
|
24
|
0.25
|
3.00
|
1.93
|
62
|
150
|
| NV
90F |
95.25
|
90.00
|
6.19
|
2.34
|
26
|
0.2
(x2)
|
6.42
|
3.06
|
66
|
188
|
| NV
120F |
126.32
|
120.00
|
7.98
|
3.12
|
29
|
0.25
(x2)
|
6.30
|
2.02
|
67
|
220
|
| NV
140F |
148.93
|
140.00
|
10.47
|
3.64
|
30
|
0.25
(x2)
|
6.37
|
4.06
|
67
|
260
|
|
POWRTROL - ENERGY SAVING EQUIPMENT
|
 |
Powrtol
temperature controlled programmer.
The
Powrmatic POWRTOL is a time and temperature control
device to be used in conjunction with warm air heaters.
The
unit contains a digital timeswitch, day thermostat
and night thermostat together with front panel mounted
switches
|
|
PAG
- INDIRECT FIRED WARM AIR CABINET HEATER
|
mpact
sized indirect natural gas fired heaters complete with atmospheric
burners and integral draught diverter.
This
series of four units are compact floor standing cabinet
air heaters that feature atmospheric gas burners, a clam
shell heat exchanger assembly and integral down draught
diverter.
A
Powrtrol controller is supplied with every heater.
 |
|
PAG
60 - 200 UD Models
|
PAG
60 - 200 UF Models
|
|
| Model |
A
|
B
|
C
|
D
|
E
|
F
|
G
|
H
|
J
|
K
|
| PAG
60 |
682
|
477
|
1550
|
255
|
220
|
125
|
110
|
389
|
475
|
609
|
| PAG
80 |
682
|
569
|
1550
|
285
|
220
|
125
|
110
|
494
|
475
|
609
|
| PAG
100 |
682
|
674
|
1550
|
285
|
220
|
150
|
110
|
599
|
475
|
609
|
| PAG
200 |
682
|
1200
|
1550
|
303
|
270
|
200
|
110
|
1125
|
460
|
609
|
|
CABINET
- INDIRECT FIRED HEATERS
|
These
are indirect gas or oil fired air heaters fitted with resiliently
mounted fan and motor assemblies, stainless steel combustion
chamber (except CPE/NCE which are mild steel) and mild steel
heat exchanger.
Heaters
are available with a comprehensive range of oil or gas fired
burners.
A Powrtrol
is supplied with every heater.
|
CP
- Indirect Fired Warm Air Cabinet Heater
|
 |
CP
100 - 1250 UF & UD Models
|
| MODEL |
A
|
B
|
C
|
D
|
E
|
F
|
G
|
H
|
J
|
K
|
L
|
| CP
100 |
730
|
603
|
1645
|
285
|
770
|
125
|
1390
|
502
|
375
|
630
|
51
|
| CP
150 |
For
CP 150 oil fired see cp 100, for cp 150 gas fired
see CP 200
|
| CP
200 |
806
|
629
|
1822
|
240
|
940
|
125
|
1530
|
527
|
453
|
706
|
51
|
| CP
300 |
857
|
730
|
2076
|
240
|
1065
|
150
|
1810
|
629
|
528
|
757
|
51
|
| CP
400 |
1060
|
908
|
2356
|
345
|
1020
|
150
|
2060
|
808
|
535
|
960
|
51
|
| CP
500 |
1365
|
908
|
2457
|
345
|
1127
|
175
|
2155
|
808
|
635
|
960
|
51
|
| CP
600 |
1365
|
908
|
2457
|
400
|
1127
|
175
|
2170
|
808
|
686
|
1264
|
51
|
| CP
700 |
1365
|
908
|
2457
|
440
|
1127
|
175
|
2170
|
808
|
686
|
1264
|
51
|
| CP
800 |
1365
|
1162
|
2381
|
440
|
1300
|
200
|
2045
|
1062
|
686
|
1264
|
51
|
| CP
1000 |
1365
|
1162
|
2381
|
440
|
1300
|
200
|
2045
|
1062
|
686
|
1264
|
51
|
| CP
1250 |
1670
|
1162
|
2381
|
440
|
1300
|
300
|
2045
|
1062
|
686
|
1570
|
51
|
|
CPE
/ NCE - Indirect Atmospheric Gas Cabinet Heaters
|
NCE
AG 100 - 200UF Models
|
CPE
AG 100 - 300UF Models
|
| Model |
A
|
B
|
C
|
D
|
E
|
F
|
G
|
H
|
J
|
K
|
| CPE-AG
100 |
809
|
631
|
1820
|
277
|
250
|
200
|
2629
|
527
|
453
|
706
|
| CPE-AG
200 |
855
|
730
|
2077
|
301
|
280
|
200
|
3182
|
629
|
528
|
757
|
| CPE-AG
300 |
1060
|
908
|
2356
|
329
|
320
|
250
|
3455
|
808
|
525
|
960
|
| NCE-AG
100 |
1340
|
631
|
1820
|
277
|
250
|
200
|
2629
|
527
|
453
|
706
|
| NCE-AG
200 |
1390
|
730
|
2077
|
301
|
280
|
200
|
3182
|
629
|
528
|
757
|
The DFU
range are direct fired cabinet style heaters in which the
products of combustion mix with the heated air being supplied
to the heated space, eliminating the need for flue.
A Powrtrol time and temperature control is supplied with every
heater
 |
|
DFU
100 - 500 Models
|
DFU
750 - 1500 Models
|
|
|
Model
|
A
|
B
|
C
|
D
|
H
|
J
|
K
|
L
|
|
DFU
100
|
603
|
908
|
1645
|
390
|
765
|
425
|
461
|
51
|
|
DFU
250
|
908
|
908
|
2051
|
590
|
765
|
575
|
765
|
51
|
|
DFU
500
|
908
|
908
|
2051
|
590
|
765
|
575
|
765
|
51
|
|
DFU
750
|
1775
|
908
|
2051
|
590
|
765
|
575
|
1625
|
51
|
|
DFU
1000
|
1775
|
908
|
2051
|
590
|
764
|
575
|
1625
|
51
|
|
DFU
1500
|
2025
|
1162
|
2229
|
590
|
1018
|
610
|
1886
|
51
|
|
WASTE
OIL FIRED MANUAL IGNITION ECONOMY HEATERS
|
 |
Thermobile
waste oil fired heaters can be operated
using waste oil from diesel or petrol engines,
gearboxes, transmissions, hydraulic systems,
diesel oil or any combination of these.
The following must not be used; solvents,
thinners, petrochemical based oils, transformer
oil or any oil above S.A.E. 90.
Full
combustion is achieved in a vaporising system
and non burnable residue is retained in
the burner pan. This system does not produce
any unpleasant smell or smoke and the emissions
from the flue stack are well below permitted
contamination levels.
|

-
CLEAN,
SOOT FREE COMBUSTION
-
CAN
BURN PURE WASTEOIL OR MIXED WITH DIESEL
-
FAST
RETURN ON INVESTMENT DUE TO FREE FUEL
-
HIGH
EFFICIENCY
-
HEATER
INCLUDES BUILT-IN-TANK, PUMB & CONTROLS
| Technical
Details |
|
AT306
|
AT307
|
AT400
|
AT500
|
| Capacity
Btu/hr (1) |
Max
|
80,000
|
80,000
|
112,000
|
170,000
|
|
Min
|
60,000
|
60,000
|
64,000
|
102,000
|
| Fuel
Consumption L/h (1) |
Max
|
2
|
2
|
2.5
|
3.8
|
|
Min
|
3
|
3
|
4.3
|
6.2
|
| Tank
Capacity |
Litres
|
50
|
50
|
55
|
55
|
| Weight |
Kg
|
67
|
84
|
130
|
175
|
|
Current
|
A
|
0.23
|
0.8
|
1
|
2
|
|
Flue
Connection
|
0mm
|
130
|
130
|
130
|
180
|
|
Heated
Airflow
|
m3/hr
|
-
|
1000
|
1000
|
3000
|
|
Max.
space to be heated (2)
|
cu.ft
|
16,000
|
16,000
|
22,400
|
34,000
|
(1)
Output depending on type of waste oil. (2)
Depending on building insulation.
|
| |
Width
|
Depth
|
Height
|
|
AT306
|
54cm
(21")
|
98cm
(39")
|
113cm
(44")
|
|
AT307
|
54cm
(21")
|
105cm
(41")
|
127cm
(50")
|
|
AT400
|
82cm
(32")
|
110cm
(43")
|
108cm
(42")
|
|
AT500
|
82cm
(32")
|
115cm
(45")
|
128cm
(50")
|
|
|
INFORMATION
RELATING TO FLUE PIPING
The
standard flue kit consists of:
Models
AT306, AT307 & AT400
1 x T Piece complete with Draught Stabiliser
4 x 1m lengths of Flue Piping (150mm dia.)
including change-over length.
1 x Terminal pipe
Model
AT500
1 x T Piece complete with Draught Stabiliser
5 x 1m lengths of Flue Piping (200mm dia.)
including
change-over length.
1 x Terminal pipe
Supports
Wall
bands are available to suit the Flues and
for wall fixed installation should be located
at 3 metre centres. The bands give a 50mm
clearance to the wall but extension brackets
are also available with depths of 50mm,
100mm, 150mm, 200mm and 250mm. When combined
with wall bands the extensions offer a wall
clearance of 50mm to 300mm.
A
Guy Wire fixing bracket is available to
provide extra lateral support where the
flue extends more than 1.5m above the last
wall band, or for inter-connection with
the roof flashing.
|
Roof
Penetrations
Flat and angled flashings of
sheet aluminium are available to provide
suitable weather cover where the flue penetrates
a roof. 'Dektite'
silicone flashings are also available and
highly recommended.
Storm
collars of aluminium are also available
and should be fitted to the pipe immediately
above the flashings.
Terminations
To
prevent leakage of rainwater into the pipe
at joints which may be exposed above roof
level, a change-over section is supplied
in the flue kit. This section of pipe is
provided with a male crimped coupling at
each end and is designed for use where the
flue passes through the roof: one end should
be installed inside the building and one
outside. any subsequent components are installed
inverted, i.e. with the male coupling upwards
and fitted and secured in the normal way.
Rain
caps are not permitted with waste oil fired
heaters. The terminal pipe is designed to
deflect rain water down the outer section.
NB.
All lengths and fittings are fabricated
from 0.55mm Type 430 Stainless Steel.
|
|
|
|
 |
|